Go to top

Protein electrophoresis, CSF, panel
Back to List
Test Name:
Protein electrophoresis, CSF, panel
Synonyms:
Oligoclonal banding
Protein isoelectric focusing, CSF
Ordering Information:
Meditech Test Code: PECSF

Testing panel includes:
•  Protein electrophoresis, CSF
  Immunoglobulin G, CSF
  Albumin, CSF
  Immunoglobulin G (IgG)
  Albumin

Testing Prerequisites:
A serum sample is required for comparison and generation of complete result profile

Collection Device/Tube Type:
3.5 mL blood - GOLD SST (gel)
Sterile CSF screw-capped tube
Collection Instructions:
Serum sample must be collected within 72 hours of CSF sample collection. Collection of serum sample at the same appointment as the CSF sample collection is preferred.

Submission Requirements:
1.5 mL CSF and 1 mL serum

Frequency of Testing:
Weekly
Reference Range:
Gel electrophoresis (isoelectric focusing) Interpretation is reported for banding in CSF compared to serum

Analysis includes:
•  Albumin
•  Albumin, CSF
•  Immunoglobulin G (IgG)
•  Immunoglobulin G, CSF

Test

Reference range

Albumin index

< 9

IgG/Albumin index

0.09 – 0.25

IgG index

0.30 – 0.85

IgG synthesis rate

-9.9 – 3.3 mg/d
(Values > 8 mg/d are increased)



Last Reviewed:
04 May 2023

Back to List