Go to top

Platelet count for in vitro clumping (Calgary/South)
Test Name:
Platelet count for in vitro clumping (Calgary/South)
Synonyms:
Clumped platelet panel
Testing Prerequisites:
Patient must have presented with clumped platelets previously
Collection Device/Tube Type:
4 mL blood - LAVENDER EDTA and 2.7 mL blood - LT BLUE CITRATE
Collection Instructions:
•  Immediate mix tube 8 - 10 times by gentle inversion
•  Make slides from both tubes of blood
•  Write on slide label EDTA or Citrate
•  Keep tubes together (with the CBC or CBCD tube) using an elastic band

Submission Requirements:
•  1 mL whole blood
•  Citrate tube must be full

Handling/Storage Comments:
Frequency of Testing:
Daily
Comments:
A routine platelet count is done to confirm a previous clumping platelet result. A clumped platelet count will then be performed on the citrate tube. 

Last Reviewed:
08 May 2023